Version 9.0.0 | |
IR2542 | User groups can now be managed. A new tab in Security allow up to 6 user groups to be given different profiles. Each operator can be assigned to a group and inherit the profile. |
IR2543 | The MAX-MIN I-Calc will now be able to display 2 channels for MAX difference, and 2 separate channels for MIN difference. |
IR2552 | Correction for Max/Min summary sheet where the interval duration was not always calculated. |
IR2553 | The group selection in the summary sheet no longer re-imports data immediately because it can be slow. The Import button must now be used. |
IR2554 | Modification to test selection in the report analysis, where tests were being constantly re-analysed. |
IR2556 | Correction in reports where user tried to add multiple group chart views to a selected position in an existing report list. |
IR2557 | Correction for CSV file import where Test Spec locations can be lost. |
IR2558 | If the folder location used by Historic Tests is modified, it was possible that many reports list entries would say ‘test not found’. This is now addressed. |
IR2560 | Correction for CSV file import where the data goes over midnight and the 24 hour time format is selected, and the end time is not prefixed by a 1 to denote a new day. |
IR2561 | Probe groups can now be assigned to different chambers, allowing user to have groups of sensors in different chambers for simultaneous testing, saving mush time!. The group reports will show correct chamber details for each chamber. |
IR2562 | Fix for CSV file import where data is formatted with 6+ characters, such as xxx.xxxx. The chart was affected by this. |
IR2565 | For importing d20 files from Grant Squirrel loggers, calibration adjustments can now be applied to the data. |
IR2569 | Correction for selecting old version data files with missing version 8 TQD file. |
IR2571 | Correction for summary sheet data storage, where a space caused an issue on some computers. |
IR2574 | Crop data functions now audits the changes, and backs all the uncropped test files up to the TQSoft Files Desktop folder. |
IR2577 | Fluke logger control window now allows multi file mouse select, making managing the files much easier! |
IR2579 | Correction for I-Calc analysis when no group settings are present and non group 1 items generate blank results. |
IR2580 | The About window should now show complete online license key. |
IR2581 | Ethernet connections with Fluke, Yokogawa and MODBUS TCP no longer work under Windows 11. TQSoft is now updated with a communications component compatible with Windows 11. |
IR2582 | Start logging window now has option to start logging at a preset time. With this option set scan timestamps will start exactly at the programmed start time. This allows battery loggers (eg Madgetech) timestamps to be co-ordinated with Fluke timestamps, and so data can be merged correctly without mismatched timestamps. |
IR2584 | Fix for Fluke LAN connection in Windows 11 |
IR2585 | 3D chamber diagram now supports probe groups in limited fashion. Each group must share same chamber dimensions. |
IR2586 | Fix for 3D chamber diagram positions table when probe selection is non consecutive. |
IR2587 | Fix for group reports when probes have been set defective. |
IR2590 | Fix for crash during logging where on restart the previous test can be corrupted. |
IR2591 | Fix for operator without Test Spec permissions where they cannot change test spec selection at start logging. |
IR2592 | Correction for issue where first operator in the user list does not have a password reminder available. |
IR2594 | Corrections for Japanese translation. |
IR2596 | Correction for Agilent RS232 connection where the COM test does not happen. |
IR2597 | Correction for Anville825 where move to 32 bit numbers was not included for this logger. |
IR2595 | Correction for calibration reports which could in certain circumstances pick up incorrect site name. |
IR2596 | Correction for RS232 communications test where Agilent logger does not have the test coded. |
IR2597 | Correction for Anville 825 where the 32 bit numbers were not implemented. |
IR2598 | Correction for audit trial where in some circumstances the user profile is not saved, |
IR2601 | Legacy mbf data file format no longer has security check. |
IR2602 | Correction for case where tqd file left open stopped OneDrive. |
IR2603 | Corrections for Japanese character set. |
IR2604 | OMSRuntime provided on install (c:\tqsoft\dinkey driver) for remote upgrade feature. |